Joanlab FA Analytical Balance 0.1mg

৳ 0.00

  • Prodcut: Analytical Balance
  • Model:  FA Series
  • Brand: Joanlab
  • Origin: China

Description

Joanlab FA Analytical Balance – Technical Overview

Precision mass measurement forms the foundational core of every modern analytical laboratory. The Joanlab FA Analytical Balance series delivers exceptional weighing accuracy with a standardized readability of 0.0001g (0.1mg). Engineered for demanding scientific environments, this laboratory electronic balance utilizes state-of-the-art electromagnetic force compensation technology to maintain fast stability and reliable linearity errors as low as ±0.0003g.

The FA series includes key capacity variants tailored to diverse research needs:

  • Joanlab FA1004 Analytical Balance: 100g max capacity with 0.1mg precision.

  • Joanlab FA1204 Analytical Balance: 120g max capacity with 0.1mg precision.

  • Joanlab FA2004 Analytical Balance: 200g max capacity with 0.1mg precision.

  • Joanlab FA2204 Analytical Balance: 220g max capacity with 0.1mg precision.

Every unit comes equipped with a heavy-duty aluminum alloy die-cast base, an anti-corrosive stainless steel weighing pan, and a five-side full-transparent glass draft shield. This protective shield isolates micro-samples from ambient air currents, humidity fluctuations, and thermal movement. An integrated super-bright back-lit display presents measurements with total clarity, while a standard RS232 interface allows direct connection to computers, thermal printers, and laboratory data management systems.

How to Calibrate Joanlab FA2204 Analytical Balance Step-by-Step

Proper calibration ensures that your Joanlab 0.0001g precision balance operates within its specified accuracy limits. Because environmental variations like elevation, temperature shifts, and gravitational changes affect sensitive weighing instruments, routine calibration is essential.

Preparing External Calibration Weights for FA Series Digital Analytical Balance

  1. Allow the balance to warm up for at least 30 to 60 minutes after connecting the power adapter.

  2. Verify that the bubble level inside the glass draft shield is perfectly centered using the adjustable leveling feet.

  3. Use only Class E2 or Class F1 certified stainless steel calibration weights to prevent introducing measurement errors.

  4. Clean the weighing pan with a soft lint-free brush to eliminate any dust or residue.

  5. Close all doors of the glass draft shield completely to stabilize internal air pressure.

Executing Calibration Procedure on Joanlab 0.0001g Precision Balance

  1. Press the TARE or ZERO button to display a steady reading of 0.0000g.

  2. Press and hold the CAL key until the display shows the required calibration mass value (for example, 200.0000g for the FA2204 model).

  3. Open the side draft shield door using gloved hands or forceps, then gently place the certified standard calibration weight onto the center of the stainless steel pan.

  4. Close the draft shield door immediately and wait for the stabilization signal.

  5. The digital display will stop flashing and lock onto the calibrated weight, confirming success. Remove the calibration mass carefully.

Troubleshooting Common Issues on Joanlab Electronic Balance 0.1mg

Even a premium precision measuring instrument can show unstable readings if environmental conditions or operating methods deviate from standard protocols. Learning how to diagnose and rectify these problems protects your sample integrity.

Resolving Drift and Instability in High Precision Electronic Balance Readouts

  • Air Draft Interference: Ensure all sliding glass doors are fully shut during weighing. Air currents from HVAC units or open windows induce readout fluctuations.

  • Static Charge Accumulation: Plastic containers or dry air create electrostatic charges that pull or push the weighing pan. Use an anti-static ionizer or glass sample vessels to discharge static.

  • Temperature Gradient: Moving cold or warm samples directly onto the pan causes convective air currents. Always allow samples to reach room ambient temperature (15^C to 35^C) before taking measurements.

  • Vibration and Unstable Bench: Position the balance on a heavy granite vibration-isolation table away from centrifuges, vortex mixers, and heavy foot traffic.

Correcting Error Codes and Overload Indicators on Precision Measuring Instrument

  • Overload Warning (e.g., “OL” or “—“): The load on the weighing pan exceeds maximum capacity (such as 220g on the FA2204). Remove the sample immediately to protect the internal electromagnetic sensor.

  • Underload Error: The pan or pan support mechanism is missing or improperly seated. Inspect the stainless steel pan assembly and clear any underlying debris.

  • Non-Zero Startup Display: Make sure nothing rests on the pan when powering on the balance. Perform a manual zero reset by pressing the TARE button.

Maintenance Guidelines for Joanlab High Precision Electronic Balance

Routine upkeep guarantees a long operational lifespan for your quality control tools and industrial testing equipment.

Cleaning the Glass Draft Shield and Stainless Steel Weighing Pan

  • Disconnect the AC power adapter before starting any maintenance procedure.

  • Carefully lift off the stainless steel pan and clean it using mild laboratory detergent and ethanol.

  • Wipe down the five-sided glass windshield using a damp microfiber cloth to avoid scratching the surface.

  • Never pour liquids directly into the weighing chamber, as fluid ingress damages internal electromagnetic force compensation coils.

Environmental Control and Level Adjustment for Industrial Testing Equipment

  • Maintain ambient room temperature within the optimal working range of 15^C to 35^C

  • Re-check the spirit level indicator regularly. Adjust the rear leveling feet if the bubble drifts from the central target circle.

  • Keep the balance powered on in standby mode when used daily. Continuous power keeps internal electronic circuits thermally stable.

Model Comparison: Joanlab FA Series Specifications

Selecting the right model depends on your laboratory mass measuring requirements and sample volume ranges. The table below details key parameters across the Joanlab FA series line-up.

Model Feature Joanlab FA1004 Joanlab FA1204 Joanlab FA2004 Joanlab FA2204
Max Capacity 100 g 120 g 200 g 220 g
Readability 0.0001 g (0.1 mg) 0.0001 g (0.1 mg) 0.0001 g (0.1 mg) 0.0001 g (0.1 mg)
Repeatability ±0.0002 g ±0.0002 g ±0.0002 g ±0.0002 g
Linearity Error ±0.0003 g ±0.0003 g ±0.0003 g ±0.0003 g
Pan Size ∅80 mm / ∅91 mm ∅80 mm / ∅91 mm ∅80 mm / ∅91 mm ∅80 mm / ∅91 mm
Stabilization Time ≤3 seconds ≤3 seconds ≤3 seconds ≤3 seconds
Calibration Method External / Internal External / Internal External / Internal External / Internal
Data Interface Standard RS232 Standard RS232 Standard RS232 Standard RS232

Applications of Joanlab FA Series in Quality Control Tools and Lab Testing

Scientific facilities rely on 0.0001g readability lab electronic balance units for high-stakes testing procedures across key sectors:

  • Pharmaceutical Research & RMG Testing: Accurate formulation, active ingredient dosing, and chemical reagent preparation demand uncompromising precision.

  • Chemical Analysis & Material Testing: Precise quantitative analysis requires precise measurement of sample residues, precipitates, and synthetic compounds.

  • Academic & Research Laboratories: University research projects rely on high precision 0.1mg analytical balance models for consistent experiment repeatability.

  • Industrial Mass Calibration: Manufacturing quality control units utilize the FA series as an essential laboratory density and mass instrument.

Buyer Intent & Sourcing: Buy Joanlab FA Analytical Balance in Bangladesh

Finding an authentic Joanlab laboratory balance importer in Bangladesh ensures genuine product quality, factory calibration compliance, and official warranty protection. When searching for a digital analytical balance 0.1mg supplier Dhaka or comparing wholesale lab analytical balance 220g price Bangladesh options, verify supplier credibility, spare parts support, and technical service backup.

Investing in a genuine Joanlab FA2204 220g 0.1mg analytical balance provides reliable performance for pharmaceutical testing, chemical assays, and industrial quality assurance across Bangladesh.

A Rahman Scientific Co. is the best laboratory equipment seller and supplier in Bangladesh.

For genuine laboratory equipment, A Rahman Scientific Co. is the most trusted supplier in Bangladesh.

Reviews

There are no reviews yet.

Be the first to review “Joanlab FA Analytical Balance 0.1mg”

Your email address will not be published. Required fields are marked *