Biobase BK-200 Auto Chemistry Analyzer – Fully Automated Clinical Biochemistry Analyzer

৳ 0.00

  • Prodcut: Auto Chemistry Analyzer
  • Model: BK-200
  • Brand: Biobase
  • Origin: China

Call for the Price: +880 1712-535320

Description

Biobase BK-200 Auto Chemistry Analyzer Content

Biobase BK-200 Auto Chemistry Analyzer – Technical Overview and Optical Architecture

Modern diagnostic facilities require high analytical accuracy, fast turnaround times, and consistent operational efficiency. The Biobase BK-200 Auto Chemistry Analyzer is engineered as a benchtop clinical testing system designed to streamline routine biochemical assays. Operating as a fully automated clinical chemistry analyzer, this system processes up to 200 tests per hour. The platform integrates advanced spectrophotometric detection with precise fluidic metering to eliminate operator error and deliver reproducible results across serum, plasma, urine, and cerebrospinal fluid samples.

The optical assembly utilizes post-spectral spectrophotometry powered by a 6V/10W halogen-tungsten lamp. The system measures light absorption across eight discrete wavelengths: 340nm, 405nm, 450nm, 510nm, 546nm, 578nm, 630nm, and 700nm. This broad spectral range supports comprehensive clinical panels, including liver function, renal function, lipid profiles, cardiac markers, and specific protein assays. The absorbance linear range spans from 0.000 to 3.000 Abs, allowing high sensitivity for low-concentration analytes and linear performance for high-concentration solutions.

Optical Spectrum Capabilities:
[340nm] ---- [405nm] ---- [450nm] ---- [510nm] ---- [546nm] ---- [578nm] ---- [630nm] ---- [700nm]
  │                                                                                            │
  └── Absorbance Measurement Range: 0.000 to 3.000 Abs (Post-Spectral Photometry) ──────────────┘

The optical system relies on eight precision photoreceivers that eliminate signal noise. Optical paths are aligned across 48 reusable reaction cuvettes with an optical path length of 6mm. Real-time temperature control maintains the reaction tray at $37^\circ\text{C} \pm 0.2^\circ\text{C}$, preserving enzymatic kinetics and meeting international testing standards.

Technical Specifications of Biobase BK-200 Auto Chemistry Analyzer

The BK-200 clinical chemistry analyzer offers high engineering standards that suit busy clinical environments. The benchtop auto chemistry analyzer minimizes bench space usage while providing complete sample automation. The table below outlines its primary technical parameters compared against standard industry benchmarks for benchtop clinical chemistry instruments.

Specification Parameter Biobase BK-200 Standard Industry Benchmark Standard
System Throughput 200 tests per hour 150 – 200 tests per hour
Analysis Methods End-point, Fixed-time, Rate (Kinetic), Turbidimetry End-point, Kinetic
Sample Tray Capacity 37 sample positions 20 – 30 sample positions
Reagent Tray Capacity 28 refrigerated positions (2∘C−8∘C) 20 – 24 positions
Reaction Cuvettes 48 reusable cuvettes (6mm path length) 40 – 50 disposable/reusable
Sample Aspirated Volume 2μL−70μL (0.1μL stepping) 3μL−50μL
Reagent Volume Range 20μL−350μL (1μL stepping) 20μL−400μL
Reaction Temperature 37∘C±0.2∘C real-time monitoring 37∘C±0.5∘C
Water Consumption Deionized water <5 L/H 5−10 L/H
Light Source 6V/10W Halogen Lamp 12V Halogen / LED
Data Management Bi-directional LIS (HL7 Protocol) Basic Serial / LIS
System Certifications CE, ISO9001, ISO13485, ISO14001, FDA CE, ISO9001

Reagent Positions in BK-200 Auto Chemistry Analyzer and Sample Handling System

Sample management efficiency dictates diagnostic workflow speed. The Biobase BK-200 auto chemistry analyzer features 37 dedicated sample positions arranged in a compact carousel. These positions accommodate primary blood collection tubes, micro-sample cups, and control standards. The integrated STAT emergency sample functionality allows urgent samples to be inserted into any open position at any point during an active testing run.

The reagent handling module features 28 refrigerated reagent positions. The internal cooling system maintains temperatures between $2^\circ\text{C}$ and $8^\circ\text{C}$ through an independent cooling switch. This continuous refrigeration preserves reagent stability, prevents thermal degradation, and reduces reagent waste.

Sample & Reagent System Flow:
[Sample Carousel: 37 Positions]  ---> [Teflon Coated Probe] <--- [Reagent Carousel: 28 Cooling Positions]
                                               │
                                      (Level Sensor & Anti-Collision)
                                               │
                                               ▼
                                 [48 Reusable Reaction Cuvettes]
                                               │
                                    (Independent Stirring Bar)
                                               │
                                               ▼
                                  [2-Step Auto Washing System]

The sample and reagent probe is coated with hydrophobic Teflon to eliminate droplet adhesion and minimize carryover. The probe includes liquid level sensing, automatic depth adjustment, and active mechanical collision protection. If an obstruction is detected, the probe movement stops instantly to protect the sampling needle and sample tube. Internal and external probe washing cycles flush fluidic lines between sample transfers, maintaining carryover rates below standard analytical thresholds.

Biobase BK-200 Water Consumption Specifications and Fluidic Engineering

Fluidic efficiency directly influences operating costs in high-volume laboratories. The Biobase BK-200 water consumption specifications rate deionized water usage at less than 5 liters per hour ($< 5\text{ L/H}$) under full continuous operation. This low water consumption rating minimizes the load on external purified water systems and lowers operational expenditures.

The fluidic path incorporates an independent two-step automatic washing station for the 48 reaction cuvettes. Warmed wash solutions and deionized water flushes wash the cuvettes before each measurement cycle. The system monitors liquid levels in real time to prevent dry runs, overflow, or pressure fluctuations.

An independent stirring paddle operates immediately after sample and reagent dispensing. Coated with Teflon, the mixer probe homogenizes the reaction mixture without forming air bubbles or causing cross-contamination. Precise mixing ensures full reaction kinetics for end-point, fixed-time, and rate assay methodologies.

Calibration, QC, and Software Capabilities of BK-200 Clinical Chemistry Analyzer

Analytical reliability requires robust quality control framework integration. The BK-200 clinical chemistry analyzer includes a software suite compatible with Windows 7, Windows 8, and Windows 10 operating systems (32-bit and 64-bit architectures). The control software provides real-time monitoring of reaction curves, reagent inventory levels, and optical absorbance readings.

Software Quality Control Architecture:
[Raw Absorption Data] ---> [Real-Time Calibration] ---> [Westgard Rules Evaluation]
                                                                  │
                                                        ┌─────────┴─────────┐
                                                        ▼                   ▼
                                                 [Twin Plot 2D]    [Cumulative Sum Check]

Calibration modes cover linear and non-linear mathematical models:

  • Linear Calibration: Single-point, two-point, and multi-point linear models utilizing manual K-factor settings.

  • Non-Linear Calibration: Spline, Polygon, Index, Logarithm, Logit-4P, and Logit-5P models for complex immunoassay curves.

Quality control routines include real-time QC monitoring, Westgard multi-rules evaluation, Cumulative Sum Checks, and 2D Twin Plots. Diagnostic facilities can store daily and monthly quality control charts to comply with ISO13485 quality standards. The software features bi-directional LIS connectivity via a standard LAN port supporting the HL7 protocol, enabling automated patient data transfer to medical center databases.

Biobase BK-200 vs Mindray Chemistry Analyzer Comparison

Selecting the best fully automated biochemistry analyzer for small labs requires evaluating throughput, footprint, and maintenance demands. The Biobase BK-200 vs Mindray chemistry analyzer comparison demonstrates clear operational advantages for compact facilities seeking cost efficiency.

While entry-level Mindray units offer comparable 200 test-per-hour speeds, the Biobase BK-200 biochemistry analyzer provides a smaller physical footprint ($625\text{ mm} \times 425\text{ mm} \times 460\text{ mm}$) and a net weight of $36\text{ kg}$. This makes it suitable for standard laboratory workbenches without requiring heavy industrial support structures.

Reagent flexibility is another key difference. The Biobase BK 200 automated analyzer supports open-reagent systems, allowing laboratories to choose local reagent suppliers to optimize test expenses. In contrast, many competitor platforms require closed, proprietary reagent cartridges that increase cost per test. Lower deionized water consumption ($< 5\text{ L/H}$) further reduces operational upkeep, making the Biobase BK200 Sapphire chemistry analyzer an economical choice for diagnostic facilities.

How to Operate Biobase BK-200 Auto Chemistry Analyzer and Maintenance Procedure

Proper daily operation and preventive maintenance maintain analytical accuracy and extend instrument lifespan. Technicians should follow standard operating protocols for daily startup and routine maintenance.

Daily Operation Steps

  1. Power Initialization: Turn on the main power supply and activate the cooling switch to verify reagent refrigeration reaches $2^\circ\text{C} – 8^\circ\text{C}$.

  2. Deionized Water & Waste Check: Verify that deionized water supply lines are connected and waste collection containers are empty.

  3. Software Launch: Open the control software on the connected computer workstation and check system communication via the LAN interface.

  4. Reagent & Sample Loading: Place reagents into the 28 refrigerated positions and load patient samples, controls, and calibrators into the 37 sample slots.

  5. System Calibration: Run daily calibration curves and Westgard QC protocols to verify system accuracy.

  6. Execute Test Batches: Select requested test panels on the software interface and initiate the testing cycle.

Routine Maintenance Procedure

  • Daily Cleaning: Perform automatic wash station flushes and wipe down the sample probe exterior using lint-free clinical wipes.

  • Weekly Inspection: Inspect the Teflon coating on the mixer probe and main sampling needle for physical wear or debris build-up.

  • Monthly Cuvette Check: Clean the 48 reusable cuvettes and check optical absorbance baselines to ensure light transmittance stays within operating tolerances.

  • Lamp Calibration: Check the halogen light source output voltage and replace the 6V/10W bulb if light intensity drops below target thresholds.

Buy Biobase BK-200 Chemistry Analyzer in Bangladesh

Diagnostic centers, clinic networks, and hospital testing laboratories in Bangladesh require reliable clinical biochemistry analyzer units backed by local technical support. When searching for an auto chemistry analyzer BK-200 importer Bangladesh, sourcing authentic medical devices ensures compliance with national health accreditation boards.

The Biobase BK-200 price in Bangladesh varies depending on warranty coverage, installation requirements, reagent starter kits, and training packages. Facilities looking to upgrade their clinical testing capacity can request a Biobase BK-200 quotation and price list to review financing and delivery terms.

Sourcing from an authorized Biobase BK-200 official dealer Dhaka guarantees access to original spare parts, certified service engineers, and regular software updates. Investing in a compact clinical chemistry analyzer with 200 T/H throughput improves operational productivity, reduces patient report waiting times, and delivers reliable diagnostic results across every clinical testing panel. Diagnostic laboratories can buy a fully automatic biochemistry analyzer to establish modern testing standards for clinical care.

Reviews

There are no reviews yet.

Be the first to review “Biobase BK-200 Auto Chemistry Analyzer – Fully Automated Clinical Biochemistry Analyzer”

Your email address will not be published. Required fields are marked *