Description
Microprocessor Dissolution Test Apparatus – Technical Overview
Pharmaceutical quality control demands absolute precision when determining the rate of active pharmaceutical ingredient release from solid dosage forms. The Microprocessor Dissolution Test Apparatus Model 1918 and Microprocessor Dissolution Test Apparatus Model 1916 represent the gold standard in automated solid dosage evaluation. Manufactured by Electronics India, these systems provide reliable, reproducible testing parameters that comply strictly with international pharmacopeia standards. Research laboratories and manufacturing units across Bangladesh utilize these systems to ensure rigorous batch-to-batch consistency.
Equipped with cutting-edge microcontrollers, both the Electronics India Dissolution Test Apparatus 1918 1916 models deliver flawless regulation of critical testing parameters. The 8 station dissolution test apparatus configuration of Model 1918 allows for high-throughput analysis, while the 6 station dissolution test apparatus design of Model 1916 balances high performance with cost efficiency. Utilizing advanced solid state lab instruments ensures your testing facility eliminates data variability caused by minor environmental shifts. Choosing an authentic microprocessor dissolution tester protects laboratory workflows from mechanical drifts and uncalibrated readings over extended operation cycles.
Technical Specifications and Engineering Standards
Structural Mechanics and Vessel Configurations
The physical architecture of the Electronics India 1918 and Electronics India 1916 centers on a durable, chemically resistant body designed for heavy-duty industrial testing equipment. The Model 1918 features an 8-vessel assembly layout, providing automated monitoring for large-scale batches. Alternatively, Model 1916 functions as a streamlined 6-vessel assembly layout, catering perfectly to focused research lines. Precise positioning of the stirring shafts relative to the vessel axes limits mechanical vibration, ensuring stable hydrodynamic conditions during active dissolution cycles.
Temperature and Speed Regulation Networks
Accurate assessment of tablet dissolution test apparatus parameters requires tight thermal and rotational management. The embedded microprocessor continually monitors water bath temperatures via integrated PT100 sensors, adjusting the internal immersion heaters smoothly to maintain an optimal $37^\circ\text{C} \pm 0.5^\circ\text{C}$ state. At the same time, the advanced digital motor driver system manages shaft rotation speeds across a comprehensive 25 to 200 RPM spectrum. This absolute consistency makes the digital dissolution apparatus 1918 variant a crucial tool for critical quality control labs.
| Engineering Parameter | Model 1918 Specifications | Model 1916 Specifications | Compliance Reference |
| Vessel Configuration | 8 Vessels (6 Active + 2 Blank) | 6 Vessels Complete Set | USP, IP, BP Standards |
| Speed Control Spectrum | 25 to 200 RPM ($\pm 1$ RPM) | 25 to 200 RPM ($\pm 1$ RPM) | ISO 9001 Production |
| Thermal Range Regulation | Room Temp to $45.0^\circ\text{C}$ | Room Temp to $45.0^\circ\text{C}$ | $\pm 0.5^\circ\text{C}$ Tolerance |
| Water Bath Structure | Clear Acrylic One-Piece Tank | Clear Acrylic One-Piece Tank | High-End Leak Proofing |
| Display Panel Interface | 16×2 Line Alphanumeric LCD | 16×2 Line Alphanumeric LCD | Solid State Design |
| Stirrer Shaft Assembly | Snug-Fit Stainless Steel 316 | Snug-Fit Stainless Steel 316 | Anti-Corrosive Polymer |
Microprocessor Dissolution Test Apparatus 1918 & 1916 Price in Bangladesh
Investment Matrix and Life-Cycle Costs
Acquiring high-tier pharmaceutical testing instruments involves evaluating initial capital outlays against long-term maintenance costs. The microprocessor dissolution test apparatus 1918 1916 price in Bangladesh reflects specialized import logistics, component durability, and advanced calibration engineering. Securing a premium, USP IP compliant 6 station dissolution testing instrument reduces instrument downtime significantly. This reliability prevents costly production delays or failed batch validation cycles in commercial manufacturing operations.
Sourcing Direct From Verified Importers
Navigating the local market requires identifying a certified scientific lab equipment dealer to avoid sub-par clones. Seeking an established Electronics India dissolution apparatus supplier in Dhaka ensures you receive verified equipment packages with traceable material roots. Many local purchasing teams rely on regional networks like Paradise Scientific Company Ltd. or look up the current Glassco Scientific dissolution apparatus price in BD to assess options. Partnering with a dedicated pharma laboratory equipment dealer Bangladesh company gives your facility access to authentic replacement parts and factory-authorized servicing.
Advanced Pharmacopeial Compliance and System Architecture
Validation Metrics and Regulatory Safety
Modern pharmaceutical processing lines face strict inspection standards enforced by global regulatory bodies. The automatic 8 vessel tablet dissolution test apparatus specifications found in the Electronics India catalog meet all essential criteria for validation tracking. This design ensures the precise alignment of the paddles and baskets mirrors the exact geometric patterns required by the United States Pharmacopeia (USP). This level of precision is vital for running valid bioavailability testing equipment trials that withstand international regulatory audits.
Microprocessor-Driven Data Management
The internal firmware of the pharma dissolution tester 1916 system records real-time run data, providing unmodifiable timestamps for sample processing intervals. Lab supervisors can program up to 20 distinct, multi-step testing methods directly into the non-volatile system memory, saving significant time during routine batch transitions. The integrated LCD continuously presents actual against targeted performance values, alerting operators instantly if speed or temperature limits diverge from programmed boundaries.
[Program Testing Protocol] ──> [Microprocessor Auto-Adjusts Heat/RPM] ──> [Real-Time LCD Tracking] ──> [Secure Data Logging]
Installation, Calibration, and Preventive Maintenance
Systematic Calibration Protocol
Learning how to calibrate Electronics India dissolution apparatus model 1916 structures involves following a strict chronological sequence. First, the technician must check mechanical wobble using a digital dial thickness gauge placed against the lower stirring shaft segment. Next, rotational speeds should be cross-verified using an external, calibrated non-contact tachometer targeted at the upper drive belt pulleys. Finally, temperature readouts must match a certified reference thermometer submerged within the active vessel fluid.
Preventive Maintenance for High-Throughput Labs
Sustaining the operational lifespan of your precision measuring instrument requires consistent, daily care. After completing a dissolution run, operators must drain the acrylic water bath completely to prevent algae formation. Wipe down the stainless steel stirring shafts with a soft lint-free cloth to remove residual acidic medium. Checking the alignment of the central driving belt every six months prevents speed variations that can compromise test data.
Procurement Guide for Pharmaceutical Facilities
-
Review official import documents to verify the origin of your primary hardware.
-
Inspect the paddle and basket surfaces to ensure zero pitting or surface scratches.
-
Confirm that a validation manual is included to simplify future regulatory audits.
-
Verify the availability of a stable voltage stabilizer to safeguard the microprocessor.
-
Choose local suppliers that offer complete on-site installation and calibration support.
Frequently Asked Questions – Dissolution Test Apparatus
What are the main differences between the Model 1918 and Model 1916 apparatus?
The primary difference lies in their station capacities. The Model 1918 functions as an 8 station dissolution test apparatus, allowing high-throughput sample analysis. The Model 1916 is configured as a 6 station system, ideal for moderate testing volumes and smaller quality control labs.
Does this equipment comply with international USP and IP pharmacopeia guidelines?
Yes, both Electronics India models are fully USP, IP, and BP compliant. They strictly maintain the specific physical dimensions, shaft configurations, and tolerances required for official regulatory testing.
How often should a microprocessor based pharmaceutical tablet dissolution tester be calibrated?
For standard pharmaceutical manufacturing plants, full calibration should occur every six months. Regular checks of temperature, rotational speed, and shaft wobble guarantee compliance with regulatory guidelines.
Can I purchase replacement vessels and paddles locally in Bangladesh?
Yes, authentic replacement parts, including glass vessels, paddles, and baskets, are readily available through authorized distributors in Dhaka. Using genuine components maintains the validity of your testing methods.
Where can I get the best microprocessor dissolution apparatus 1916 wholesale price BD?
You can get competitive wholesale pricing and full technical support by contacting authorized industrial testing equipment importers based directly in the Dhaka commercial zone.
A Rahman Scientific Co. is the best laboratory equipment seller and supplier in Bangladesh.
For genuine laboratory equipment, A Rahman Scientific Co. is the most trusted supplier in Bangladesh.


























Reviews
There are no reviews yet.